Issues

As you go through Designer, there will be occasions where something has been configured incorrectly. These will be shown by the Issues icon . These issues, and more will also be shown when you Upload.

If any issues are found, the Issues tab will be opened automatically and a description of each issue will be listed so that you can take corrective action (or you can ignore and proceed if you like):

Issue - '?' will provide the specific details: Solution
RIO A doesn't provide frequency band ? Adjust the number of bands on the RIO A
? doesn't support Analog Input Change the Trigger or Controller/Remote Device type
? doesn't support Digital Input Change the Trigger or Controller/Remote Device type
? doesn't support DMX Input  
? doesn't support eDMX pass-through Change the controller
? doesn't support MIDI In Change the device setting in the Midi Input trigger to a device with MIDI Input
TPC has patch on DMX 1 but hasn't been configured with an EXT or a proxy LPC Configure an EXT or DMX Proxy, or change the patch to eDMX
? is not a TPC Change the TPC triggers to match a TPC
? is not found in the project Add the remote device to the project
? isn't configured to receive DMX Input Configure the DMX input for the controller
? must be configured as an Audio input device Change the Mode of the RIO A to Audio
? must be configured to have a held timeout for digital inputs Set a held timeout in the controller interfaces
? must be configured to have a repeat interval for digital inputs Set a repeat interval in the controller interfaces
? must be configured to have an EXT Configure an EXT for the specified controller
A content target hasn't been set Select a content target for the action
A group hasn't been set Select a group for the action
A location must be set in Project Properties for waypoint timelines to operate correctly Set a location for the project
A property hasn't been set Set the properties for the action
A scene hasn't been set Select a scene for the action
A timeline hasn't been set Select a timeline for the action or condition
All inputs on ? should be configured as either digital inputs or contact closures Configure all inputs on the Controller or Remote Device
Button number hasn't been set Set a button number on the BPS button condition
Content target transitions are only supported on VLC+ Add a VLC+ to your project, or remove the action
Controller doesn't have a MIDI Out port Change the configured controller to a controller with a MIDI Output (LPC)
Controller has configured serial port 2 but the associated device only has one serial port Change the serial port number in the serial input and/or output to 1
Controller has live video programming but the associated device hasn't been upgraded to support video capture Remove the Live Video preset, or add a LPC X with video capture card or a VLC/VLC+
Controller has no fixtures patched to it Patch one or more fixtures to the controller
Controller is configured to receive DMX Input but the associated device doesn't support DMX Input Change the DMX input to an eDMX source
Controller is configured with an EXT but the associated device has no attached EXT

Connect the TPC to an EXT, ensure EXT is in v2 or uncheck the Configure EXT box

Controller is not a TPC Change the controller associated with the TPC actions to a TPC
Controller is outputting KiNET so you must ensure that the protocol network interface is on the same network as the patched power supplies Configure the Network 2 (Protocol) settings to the same network as the KiNet power supplies
Controller isn't associated with a device Associate the controller with an attached device.
Device number is not set Set a remote device number
Device type is not set Set a remote device type
Digital Word is not supported on ? Change the remote device type
eDMX pass-through for universe ? requires a controller with at least ? DMX ports  
eDMX pass-through requires TPC to be configured with an EXT Configure the TPC with an EXT
A trigger hasn't been set Select a trigger in the Enqueue Trigger action
Ethernet bus ? uses port ? which clashes with the internal web server and will prevent correct operation Change the HTTP port or the ethernet bus port
Input ? must be configured as a digital input or contact closure Change the input to a Digital or Contact Closure
Input ? must be configured as an analog input Change the input to Analog
Input ? of ? must be configured as a digital input or contact closure Change the input on the remote device to a Digital or Contact Closure
Input ? of ? must be configured as an analog input Change the input on the remote device to Analog
Input number hasn't been set Set an Input number on the trigger/condition
Interface font is not found Choose a different font for the interface
Location hasn't been set in Project Properties Set a location in the project properties
No colours have been enabled Select at least one colour in the Set RGB action/s
No DALI interface is selected Select a DALI interface
No DMX port is selected

Select a DMX port in the eDMX pass through action

No error has been selected to check Select an error in the DALI ballast error
No group has been set to release Select a group in the Release All action
No interface has been chosen Add an interface to the TPC
No page has been assigned Select a page in the Set TPC Page action
No script has been assigned Select a Script in the Run Script Action
No targets have been set to release Configure the Release All action
Not set to match any data Set the input string for the trigger
Not set to send any data Set the string to output
Note On with zero velocity will never match Reconfigure the MIDI input
Power supply has an invalid IP address Set a valid IP address for the KiNET Power Supply
Source is not set Set the Bus for the Ethernet Input
Source media is not found Replace the source media
The associated device is missing its memory card Replace the memory card
The associated device is not online Reassociate the controller, or reconnect the controller
The associated device is on the wrong network Change the network settings of the controller or computer
The associated device is running the wrong firmware Reload firmware
The associated device's memory card is corrupt Replace the controller's memory card
The associated device's memory card is read-only Unlock the memory card
The chosen audio bus doesn't have band ?

Increase the number of audio buses on the RIO A

The chosen audio bus has no input assigned to it Change the audio bus, or link a RIO A to the audio bus
The chosen timecode bus has no input assigned to it Change the timecode bus, or link a timecode source to the timecode bus
The same variable is used to select the BPS number and the button number Change the variable number to use for the BPS or button
The same variable is used to select the IP address and the port Change the variable numbers to use for the IP address or port
The same variable is used to select the slot name and set the slot value Change the variable numbers to use for the slot name and slot value
The script has no source Check the source of the script
The script has not compiled Check the source of the script for errors
The serial port of ? is set to DMX Out Change the Serial port to a serial protocol, or choose a different port
The serial port of ? must be set to DMX Input Change the Serial port to DMX input, or choose a different port
The serial port of ? must be set to RS232 or RS485 Change the Serial port
The slot name has not been set Set a slot name for the Set Text Slot action
There is only 1 serial port on ? Change the serial port number to 1

Related Topics Link IconRelated Topics